Toshiba lf546 User Manual
−
51 −
6 F 8 A 0 9 3 4
○ Detailed configuration
When you select "DETAILED" in the menu configuration selection screen, the check/change menu for
each constant setting is expanded as shown in the table below.
each constant setting is expanded as shown in the table below.
Function 1
2 3
4
5
6
7
A
DETECTOR
Exciting
Current *1
Current *1
Meter size
*3
*3
Exciting
frequency
*3
frequency
*3
Flow
direction *1
direction *1
Returns to
meas.
mode
meas.
mode
B
DUSPLAY
Display1 Display2
Custom
Value *1
Value *1
Custom
Unit *1
Unit *1
Returns to
meas.
mode
meas.
mode
C
RANGE
Range type
*1
*1
Range1 *1
Range2 *1
Range3 *1
Range4 *1
Range
Hysteresis *1
Hysteresis *1
Returns to
meas.
mode
meas.
mode
D
FILTER
Damping
value
value
Limit rate
Limit time
Returns to
meas.
mode
meas.
mode
E
LOW CUT
Low cut
value
value
Display low
cut setting
cut setting
Returns to
meas.
mode
meas.
mode
F
ZERO
Still water
zero point
adjustment
zero point
adjustment
Manual zero
setting
setting
Returns to
meas.
mode
meas.
mode
G
4-20mA
Current
output
setting upon
alarm
occurrence
*1
output
setting upon
alarm
occurrence
*1
Low limit
Value *1
Value *1
Returns to
meas.
mode
meas.
mode
H
DO
Digital
output1
*1
output1
*1
Digital
output2
*1
output2
*1
DO1 alarm
Status *1
Status *1
DO2 alarm
Status *1
Status *1
Returns to
meas.
mode
meas.
mode
I
DI
Digital input
*1
*1
DI control
signal level
*1
signal level
*1
Returns to
meas.
mode
meas.
mode
J
CNT/PLS
Count rate
*1
*1
Pulse width
setting
mode
*1
setting
mode
*1
Pulse width
*1
*1
Returns to
meas.
mode
meas.
mode
K
PRESET C
Preset count
value
*1
value
*1
Preset
output
function
*1
output
function
*1
Returns to
meas.
mode
meas.
mode
L
H/L ALM1
High alarm
ON/OFF
*1
ON/OFF
*1
High alarm
Value
*1
Value
*1
Low alarm
ON/OFF
*1
ON/OFF
*1
Low alarm
value
*1
value
*1
Returns to
meas.
mode
meas.
mode
M
H/L ALM2
HH alarm
ON/OFF
*1
ON/OFF
*1
HH alarm
Value
*1
Value
*1
LL alarm
ON/OFF
*1
ON/OFF
*1
LL alarm
value
*1
value
*1
Returns to
meas.
mode
meas.
mode
N
SELF CHK
Self check
ON/OFF *1
ON/OFF *1
Returns to
meas.
mode
meas.
mode
O
FIX OUT
Fix out set
*1
*1
Fix current
Value *1
Value *1
Fix pulse
Value *1
Value *1
Returns to
meas.
mode
meas.
mode
P
OTHERS
Password
*1
*1
LCD
adjustment
adjustment
Switch
position
position
Returns to
meas.
mode
meas.
mode
Q
COMM
PROFIBUS
*1
*1
Returns to
meas.
mode
meas.
mode
R
CAL
0%
Flow value
calculation
*1
Flow value
calculation
*1
50%
Flow value
calculation
*2
Flow value
calculation
*2
100%
Flow value
calculation
*1
Flow value
calculation
*1
Exciting
current
display
*2
current
display
*2
Returns to
meas.
mode
meas.
mode
Note 1: If you enter a wrong password, you are allowed to check the setting value and to
perform calibration for the items with *1 mark in the table. However you are not
allowed to change the setting and perform calibration for these items.
allowed to change the setting and perform calibration for these items.
Note 2: The items with*2, you are only allowed to check the calibration value.
Note 3: The items with*3, you are only allowed to check the setting value.
Note 3: The items with*3, you are only allowed to check the setting value.