meets the pulse duration for a specific magnitude where the AF < 1, means that there can be no 
other overshoot/undershoot events, even of lesser magnitude (note that if AF = 1, then the event 
occurs at all times and no other events can occur).
Note 1: Activity factor for common clock AGTL+ signals is referenced to BCLK[1:0] frequency.
Note 2: Activity factor for source synchronous (2x) signals is referenced to ADSTB[1:0]#.
Note 3: Activity factor for source synchronous (4x) signals is referenced to DSTBP[3:0]# and 
DSTBN[3:0]#.
3.3.5
Reading Overshoot/Undershoot Specification Tables
The overshoot/undershoot specification for the Pentium 4 processor is not a simple single value. 
Instead, many factors are needed to determine the over/undershoot specification. In addition to the 
magnitude of the overshoot, the following parameters must also be known: the width of the 
overshoot and the activity factor (AF). To determine the allowed overshoot for a particular 
overshoot event, the following must be done:
1. Determine the signal group that the particular signal falls into. For AGTL+ signals operating 
in the 4x source synchronous domain, use Table 18. For AGTL+ signals operating in the 2x 
source synchronous domain, use Table 19. If the signal is an AGTL+ signal operating in the 
common clock domain, use Table 20. Finally, all other signals reside in the 33MHz domain 
(asynchronous GTL+, TAP, etc.) and are referenced in Table 21. 
2. Determine the magnitude of the overshoot or the undershoot (relative to V
SS
).
3. Determine the activity factor (how often does this overshoot occur?).
4. Next, from the appropriate specification table, determine the maximum pulse duration (in 
nanoseconds) allowed.
5. Compare the specified maximum pulse duration to the signal being measured. If the pulse 
duration measured is less than the pulse duration shown in the table, then the signal meets the 
specifications.
Undershoot events must be analyzed separately from overshoot events as they are mutually 
exclusive. 
3.3.6
Determining if a System Meets the Over/Undershoot Specifications
The overshoot/undershoot specifications listed in the following tables specify the allowable 
overshoot/undershoot for a single overshoot/undershoot event. However most systems will have 
multiple overshoot and/or undershoot events that each have their own set of parameters (duration, 
AF and magnitude). While each overshoot on its own may meet the overshoot specification, when 
you add the total impact of all overshoot events, the system may fail. A guideline to ensure a 
system passes the overshoot and undershoot specifications is shown below. Results from 
simulation may also be evaluated by utilizing the Intel
®
 Pentium
®
 4 Processor Overshoot Checker 
Tool through the use of time-voltage data files.
1. Ensure no signal ever exceeds V
CC
 or -0.25V OR
2. If only one overshoot/undershoot event occurs, ensure it meets the over/undershoot 
specifications in the following tables OR
3. If multiple overshoots and/or multiple undershoots occur, measure the worst case pulse 
duration for each magnitude and compare the results against the AF = 1 specifications. If all of