2.3  AT\Qn  Flow control 
Execute command 
AT\Q<n> 
Response 
OK 
Parameter 
<n> 
AT\Q0 
No flow control 
 
AT\Q1 
XON/XOFF software flow control 
 
AT\Q2 
Only CTS by DCE 
 
AT\Q3 
RTS/CTS hardware flow control 
Required for the following procedures: incoming 
or outgoing data calls, fax calls, GPRS connec-
tions, CYCLIC SLEEP modes set with AT+CFUN. 
Often, the initialization routine of Fax programs in-
cludes enabling RTS/CTS handshake, eliminating 
the need to issue AT\Q3 once again. 
 
Reference 
 
Note 
Line state refers to RS-232 levels. 
The setting of AT\Q is stored volatile and must be restored each time after the 
GSM engine was switched off. Also, there is no way to store AT\Q to the user 
defined profile. 
See also Chapter 1.6 for general information on flow control. 
 
 
2.4  ATA  Answer a call 
Execute command 
ATA 
TA causes remote station to go off-hook (e.g. answer call). 
Note1
: 
Any additional commands on the same command line are ignored. 
Note2:
 
This command may be aborted generally by receiving a character during 
execution. It can´t be aborted in some connection setup states, such as 
handshaking. 
 
Response 
Response in case of data call, if successfully connected: 
CONNECT<text> TA switches to data mode. 
 
 
Note:
 <text> output only if +ATX parameter setting with value > 0. 
 
Response in case of voice call, if successfully connected: 
OK 
 
When TA returns to command mode after call release: 
OK 
 
Response if no connection: 
NO CARRIER 
 
Parameter 
 
Reference 
V.25ter 
Note 
See also AT+ATX and Chapter 9.1.5 for <text>