Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 202 of 256 
15.07.2002 
 
8.15  AT^SMGO  Set or query SMS overflow presentation mode or query SMS 
overflow 
Test command 
AT^SMGO=? 
Response 
^SGMO: (list of supported <n>s) OK 
Parameter 
See write command 
 
Read command 
AT^SMGO? 
Response 
TA returns overflow presentation mode and SMS overflow status 
^SGMO: <n>,<mode> OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameter 
See write command 
 
Write command 
AT^SMGO=<n> 
Response 
TA sets overflow presentation mode 
OK 
Parameter 
<n>  
SMS overflow presentation mode 
 
0 disable (default) 
 1 
enable 
 
<mode>   SMS overflow status 
 0 
space 
available 
 
SMS buffer full (buffer for received short messages is <mem3>. See 
AT+CPMS in Chapter 5.11. 
 
Buffer full and new message waiting in SC for delivery to ME 
 
 
Unsolicited result code 
When the SIM overflow status changes, a URC is sent to TE. This requires a cor-
rect setting for SMS indications (AT+CNMI=3,1; see Chapter 5.10)
 
^SMGO: <mode> 
Parameter 
See write command 
 
During data calls, a status change is indicated via a Break (100 ms). The Break 
signal will be sent each time when a status change is detected.  
 
Reference 
Siemens 
Note 
·  Incoming Class 1 short messages (ME specific) will be preferably stored to 
“ME” and may be transferred to the “SM” storage if “ME” is used up. Incoming 
Class 2 messages (SIM specific) will be placed to the “SM” storage only. 
If messages with different classes are received, the ^SMGO: 2 indication may 
be presented, without prior indication of ^SMGO: 1. The indication ^SMGO: 1 
means that both buffers ("ME" and "SM") are full. See also Chapter 5.11. 
·  For more information regarding SIM and ME specific message classes refer to 
<dcs> and the following specifications: GSM 03.38 and 3GPP TS 23.038.