Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 207 of 256 
15.07.2002 
 
8.21  AT^SNFI  Set microphone path parameters 
Test command 
AT^SNFI=? 
Response 
^SNFI: (list of supported <inBbcGain>s), (list of supported <inCali-
brate>
s) OK 
Parameters 
See write command 
 
Read command 
AT^SNFI? 
Response 
^SNFI: < inBbcGain >, <inCalibrate> OK 
Parameters 
See write command 
 
Write command 
AT^SNFI=<inBbcGain>,
<inCalibrate> 
Response 
TA sets microphone path amplifying. 
OK 
 
 
Parameters 
<inBbcGain> 
Setting for ADC gain Amplifier 0 - 7 (0=0dB, 7=42dB, 
8 steps of 6 dB)  
<inCalibrate> 
Multiplication factor 0 – 32767 for input samples at-
tenuation=20*log (inCalibrate/32767)  
 
Reference 
Siemens 
Note 
·  The read and write commands refer to the active audio mode. 
·  The write command works only in audio modes 2 to 6. 
·  The range of <inCalibrate> is up to 65535 but will be suppressed to 
32767. Values above <inCalibrate> = 65535 will cause a failure. 
·  Changed values need to be stored with AT^SNFW for use after re-
start. 
·  Attention! When you adjust the audio parameters avoid exceeding the 
maximum allowed level. Bear in mind that exposure to excessive lev-
els of noise can cause physical damage to users!