Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 23 of 256 
15.07.2002 
 
2.6  ATD><mem><n>  Originate call to phone number <n> in memory <mem> 
This command allows you to dial a phone number from a specific phonebook. To initiate a call, enter 
a two letter abbreviation for the phonebook <mem>, followed by the memory location <n> of the de-
sired entry. The location range of each phonebook can be queried by AT+CPBR (see Chapter 4.32)
 
Execute command 
ATD><mem> 
<n>[<mgsm>][;] 
TA attempts to set up an outgoing call to the specified number. 
Note: 
This command may be aborted generally by receiving a character during 
execution. Abortion is not possible during some states of connection 
setup such as handshaking. 
 
Response 
If error is related to ME functionality
+CME ERROR: <err> 
 
If no dialtone (parameter setting ATX2 or ATX4): 
NO DIALTONE  
 
If busy (parameter setting ATX3 or ATX4): 
BUSY 
 
If connection cannot be set up: 
NO CARRIER 
 
If successfully connected and non-voice call: 
CONNECT<text>
 TA switches to data state. 
    
Note:
 <text> output only if +ATX parameter setting with value > 0. 
 
When TA returns to command mode after call release: 
OK 
If successfully connected and voice call: 
OK 
 
 
Parameter 
<mem> phonebook: 
 
"SM”   SIM  phonebook (storage depending on SIM card) 
 
”FD”   SIM  fixdialling phonebook (pos. 1-7) 
 
”LD”   SIM  last-dialling-phonebook (usually the last 10 numbers di-
aled are stored on the SIM card, no matter whether or not the 
calls were successfully set up) 
 
”MC”  ME missed (unanswered received) calls list (up to 10 numbers)
 
”RC”   SIM received calls list 
 
”ME”  ME Phonebook (up to 50 numbers) 
 
”ON”   SIM (or ME) own numbers (MSISDNs) list 
 Note: 
 
<mem> must be included in quotation marks (""), if parameter 
<mgsm> is used. If not, quotation marks are optional. 
 
<n> 
Integer type memory location in the range of locations available in 
the selected memory, i.e. the index number returned by AT+CPBR.