AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 68 of 256 
15.07.2002 
 
4.4  AT+CAOC  Advice of Charge information 
Test command 
AT+CAOC=? 
Response 
+CAOC:
 (list of supported <mode>s) OK 
Parameter 
See write command 
 
Read command 
AT+CAOC? 
Response 
+CAOC: <mode> OK 
Parameter 
See write command 
 
Write command 
AT+CAOC=<mode> 
Response 
TA sets the Advice of Charge supplementary service function mode. 
If error is related to ME functionality: 
+CME ERROR: <err> 
If <mode>=0, TA returns the  current call meter value 
OK 
 
Parameter 
<mode>  0 query CCM value 
<ccm> 
string type; three bytes of the current CCM value in hexadecimal 
format (e.g. “00001E” indicates decimal value 30); bytes are simi-
larly coded as ACMmax value in the SIM 000000-FFFFFF 
 
Execute command 
AT+CAOC 
Response 
TA returns the  current call meter value 
If error is related to ME functionality: 
+CME ERROR: <err> 
If <mode>=0, TA returns the current call meter value 
+CAOC: <ccm> OK 
 
Parameter 
See write command 
 
Reference 
GSM 07.07 