Estate tgs325mq Installation Instruction

Page of 16
8
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and channel lock pliers to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the 
“on” position.
2. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
4. Remove cooktop burner caps and grates from parts 
package. Burner caps should be level when properly 
positioned. If burner caps are not properly positioned, 
surface burners will not light. Place burner grates over 
burners and caps.
5. Plug into a grounded 3 prong outlet.
Electronic Ignition System
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of 
standing pilots. When the cooktop control knob is turned to the 
“LITE” position, the system creates a spark to light the burner. 
This sparking continues, as long as the control knob is turned to 
“LITE.”
When the oven control is turned to the desired setting, sparking 
occurs and ignites the gas.
Check Operation of Cooktop Burners
Standard Surface Burners
Push in and turn each control knob to the “LITE” position. 
The flame should light within 4 seconds. The first time a burner is 
lighted it may take longer that 4 seconds to light because of air in 
the gas line. 
If burners do not light properly:
Turn cooktop control knob to the “OFF” position. 
Check that the range is plugged in and the circuit breaker has 
not tripped or the fuse blown. 
Check that the gas shutoff valves are set to the “open” 
position. 
Check that burner caps are properly positioned on burner 
bases.
Repeat start-up. If a burner does not light at this point, contact 
your dealer or authorized service company for assistance.
A. Gas pressure regulator
B. Use pipe-joint compound
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound
H. Adapter
A. Gas pressure regulator shutoff valve
A. Closed valve
B. Open valve
A
B
C
D
E
F
G
H
A
A
A. Burner base
B. Burner cap
C. Burner grate
A
B
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING