LOCATING YOUR GRILL
When determining a suitable location for your Summit
®
 gas grill installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and 
keeping any gas supply lines as short as possible. Never locate the Summit
®
 gas grill in a garage, breezeway, shed, under an unprotected overhang, or other 
enclosed area. Locate the grill and structure so there is enough room to safely evacuate the area in case of a fi re.
CLEARANCE FROM SURFACES OR STRUCTURES
WARNING: Clearance from any surface or structure is 
24 inches (609.6 mm) from the back and sides of the grill. 
Refer to “Typical Gas Supply Installation” before starting 
installation.
WARNING: The structure, “island”, countertops, and 
adjacent work areas for the built-in grill installation must be 
built from noncombustible materials only.
NOTE: If you have questions on what materials are considered noncombustible, 
contact your local building materials supplier or fi re department.
 
A
ny 
S
ur
face
Any Surface
24 inches (61 cm) Any Surface
24 inches 
(61 cm)
24 inches 
(61 cm)
Grill Frame
Note: For a countertop treatment: Recommended 3/4 inch 
(19.1 cm) overhang. Notch front edge for frame to fully 
slide in.
27 inches (685.8 mm) min. for 
lid clearance
1
3
2
SUMMIT
®
 BUILT-IN LP GAS GRILL INSTALLATION GUIDE
PLATINUM D4 , D6
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
ALL DIMENSIONS ARE TO FINISHED SURFACES.
 
WARNING: All countertop fi nished surfaces must be 
constructed of a noncombustible material.
Built-In Cutout Dimensions
D4
D6
Tolerances
1
30 
1/4
˝
38 
1/4
˝
1/4
”   - 
1/4
˝
2
34 
1/4
˝
34 
1/4
˝
1/4
”   - 
1/4
˝
3
21˝
21˝
1/4
”   - 
1/4
˝
THIS GAS APPLIANCE IS DESIGNED 
FOR OUTDOOR USE ONLY.
42369