INSTALLATION MANUAL
CHECKING INSTALLATION 
To check if the device is installed and engaged properly, open the 
Microwave Drawer fully and gently apply medium force in the 
center of the handle until movement of the appliance is detected. 
Continue pressing until the Anti-Tip bracket is engaged and move-
ment stops. A small amount of movement is acceptable at the back 
of the appliance top, but it should be stable and not tip once the 
Anti-tip bracket is engaged. Stop pressing on the Microwave Drawer 
handle and close.
To check that the unit will not slide out, open the Microwave Drawer 
fully and then apply gentle outward pressure. The unit should not 
slide toward you. If the unit does slide, check installation beginning 
with 
C
 on page 5.
ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage and fre-
quency, and connected to an individual, properly grounded branch 
circuit, protected by a circuit breaker or fuse having amperage as 
noted on the rating plate. (Rating Plate is located on the faceplate 
behind the Microwave Drawer front.) See Figure 16.
Breaker or fuse size:
240V
40 Amps
208V
40 Amps
    NOTE: Check Local Codes for required breaker size.
All electrical wiring and hookup for this appliance should be by a 
qualified electrician.
Be familiar where the main appliance disconnect is located.
Check with local utilities for electrical codes which apply in your 
area. Failure to wire your appliance according to governing codes 
could result in hazardous conditions. If there are no local codes, your 
appliance must be wired and fused to meet the requirements of the 
National Electrical Codes, ANSI/NFPA No. 70-Latest Edition. 
Effective January 1, 1996, the national Electrical Code requires that 
new, but not existing, construction utilize a four-conductor connec-
tion for this appliance class. When installing this appliance in new 
construction, a mobile home, recreational vehicle or an area where 
local codes prohibit grounding through the neutral conductor, follow 
the instructions in the section on NEW CONSTRUCTION AND 
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTOR.
  
ELECTRICAL SHOCK HAZARD
  •  Electrical ground is required on this appliance.
  •  Do not connect to the electrical supply until appliance is 
permanently grounded.
  •  DISCONNECT POWER TO THE CIRCUIT BREAKER 
OR FUSE BOX BEFORE MAKING THE ELECTRICAL 
CONNECTION.
  •  This appliance must be connected to a grounded, metallic, 
permanent wiring system or the grounding connector of the 
power cord should be connected to the grounding terminal or 
wire lead on the appliance.
  •  Do not use a gas supply line for grounding this appliance.
  •  Failure to heed these warnings could result in a fire, personal 
injury or electrical shock.
I
 
MAKE SURE THE EDGE OF THE COUNTERTOP FITS 
FLUSH AGAINST THE END OF THE FRONT CONTROL 
PANEL.
 
See Figure 15.
Figure 15
Rating plate
Figure 16