Zebra 50-12500-066 User Manual
USER PREFERENCES & MISCELLANEOUS SCANNER OPTIONS 5 - 19
Decode Session Timeout
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from
numbers. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan
the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on
the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on
Timeout Between Decodes, Same Symbol
Parameter # 89h
Use this option in presentation mode and Continuous Bar Code Read mode to prevent the beeper from
continuously beeping when a symbol is left in the linear imager scanner's field of view. The bar code must be
out of the field of view for the timeout period before the scanner reads the same consecutive symbol. It is
programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.5 seconds.
continuously beeping when a symbol is left in the linear imager scanner's field of view. The bar code must be
out of the field of view for the timeout period before the scanner reads the same consecutive symbol. It is
programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.5 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric
bar codes from
bar codes from
that correspond to the desired interval, in 0.1 second
increments.
Timeout Between Decodes, Different Symbols
Parameter # 90h
Use this option in presentation mode or Continuous Bar Code Read to control the time the scanner is inactive
between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds.
The default is 0.2 seconds.
between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds.
The default is 0.2 seconds.
To select the timeout between decodes for different symbols, scan the bar code below, then scan two numeric
bar codes from
bar codes from
that correspond to the desired interval, in 0.1 second
increments.
Decode Session Timeout
Timeout Between Decodes, Same Symbol
NOTE
Timeout Between Decodes, Different Symbols cannot be greater than or equal to the Decode Session
Timeout.
Timeout.
Timeout Between Decodes, Different Symbols