11 - 18 LI4278 Product Reference Guide
UPC-E1 Preamble
Parameter # 24h
Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are 
three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit 
System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to 
match the host system. 
No Preamble (<DATA>)
(00h)
*
System Character (<SYSTEM CHARACTER> <DATA>)
(01h)
System Character & Country Code
(< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)