1 - 14 LI4278 Product Reference Guide
Inserting the Linear Imager Scanner in the Cradle 
Insert the linear imager scanner in the cradle so that the metal contacts on the bottom of the linear imager 
scanner handle touch the contacts on the cradle. Push the handle lightly to ensure a proper connection, 
engaging the contacts in the cradle and linear imager scanner. Ensure the desk/wall mount converter knob on 
the back of the cradle is in the correct position for the horizontal or vertical mounting.
Inserting Linear Imager Scanner in the CR0078-S/CR0008-S Cradle
Horizontal Cradle Mount
When mounting the cradle horizontally, where no fastening is necessary:
1.
Ensure the rubber feet are attached to the cradle. These feet provide traction and prevent surface damage.
2.
Ensure the desk/wall mount converter knob is in the position shown in 
Figure 1-10    
Horizontal Mount - Inserting the Linear Imager Scanner in the Cradle
Vertical Cradle Mount
When mounting the cradle vertically:
1.
Ensure the rubber feet are attached to the cradle. These feet provide traction and prevent surface damage.
2.
Ensure the convertible mount hook on the front of the cradle is inserted with the hook facing up. If not, 
remove and reverse the hook so that it is in position to secure the linear imager scanner in place. (See 
 for the location of the convertible mount hook.)
NOTE
References to mounting the cradle only apply to the CR0078-S/CR0008-S cradle (not the CR0078-P 
cradle).
Desk/Wall Mount
Converter Knob