16
BATTERY CHECK AND REPLACEMENT
A silver battery powers the TTL meter and
electronic shutter.  The power circuit is on only
when you depress the shutter release (lightly for
meter reading and completely for electronic
shutter) with the shutter speed dial set at
"AUTOMATIC".  When not operating the camera, be
sure to keep the shutter dial off the "AUTOMATIC"
setting and set to any mechanical shutter setting,
so that you prevent wasting battery power if the
shutter release button is accidentally depressed.
The battery lasts about one year.  To check its life,
set the shutter speed dial at "AUTOMATIC", and
push the black check button alongside the exposure
factor control dial.  If the meter needle drops to the
notch facing "30", the battery has sufficient
capacity.  If it does not, replace the battery.  (If
you release the shutter at "AUTOMATIC" setting
when the battery is dead, the shutter will operate
at the mechanical speed of 1/1000 sec.)
For replacement, use Eveready #544 6V silver
battery.  Open the battery housing cover on the
body front.  When inserting, be sure that the (-) of
the battery faces inward.
Caution:  Do not throw a dead battery into fire, as
it may explode.  Also, keep beyond the reach of
small children.