ACS b User Manual

Page of 37
 
Chapter 6: Troubleshooting 
27 of 37 
 
Chapter 6:  Troubleshooting 
6-1  Introduction 
The utmost in safety precautions should be observed at all times when working on or around 
the machine and the electrical components. All normal trouble-shooting must be 
accomplished with the power off, line fuses removed, and with the machine tagged as out of 
service.  
The use of good quality test equipment cannot be over-emphasized when troubleshooting is 
indicated. Use a good ammeter that can measure at least twice the AC and DC current that 
can be encountered for the machine. Be sure that the voltmeter has at least minimum 
impedance of 5,000 OHMS-per-volt on AC and 20,000 OHMS-per-volt on DC scales. 
Popular combination meters, VOM and VTVM can be selected to provide the necessary 
functions. 
Before making haphazard substitutions and repairs when defective electrical components are 
malfunctioning, we recommend that you check the associated circuitry and assemblies for 
other defective devices. It is common to replace the obviously damaged component without 
actually locating the real cause of the trouble. Such hasty substitutions will only destroy the 
new component. Refer to wiring diagrams and schematics. 
Locating mechanical problems, should they occur, is relatively straightforward. When 
necessary, refer to the parts catalog section. 
 
6-2  Electrical Faults 
 
Problem 
Possible Cause 
Possible Remedy 
Motor fails to start 
Supply failure 
Check fuses 
Starter inoperative 
Check main supply 
Starter overloads or cuts out 
Check motor requirements and 
adjust accordingly 
Safety switches inoperative 
Check and adjust as needed 
Motor starts but will not take 
load 
Too much belt tension 
Check belt tension and adjust as 
necessary 
Incorrectly connected  motor 
Check terminal connection with 
manufacturer’s connection 
diagram and adjust as necessary 
Defective starter winding 
Check current in each phase 
with ammeter, if there is a 
marked difference in current in 
one phase, contact motor 
manufacturer 
Motor will start when 
disconnected from load but not 
when connected 
Worn bearings 
Check and replace if necessary 
according to manufacturer’s 
literature