Epson S1F70000 User Manual

Page of 243
S1F71100 Series
S1F70000 Series
EPSON
4–37
Technical Manual
S1F71100
Series
Power Off Function
S1F71100 can control circuit operations according to
external signal control. When the POFFX pin is con-
nected to the V
SS
 level, all circuits stop their operations
and their powers are turned off. The current consump-
tion at the power off state is less than 1
µ
A. When the
power is off, the SWO pin is at the V
DD
 level and turns
off the voltage transistor. The voltage at the SSCAP pin
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Applicable Pin
Rated Value
Unit
Input voltage
V
DD
V
DD
15.0
V
Voltage at V
O
 pin
V
O
V
O
V
SS
–0.3 to V
DD
+0.3
V
Voltage at POFFX pin
POFFX
POFFX
V
SS
–0.3 to V
DD
+0.3
V
Voltage at ERCAP pin
ERCAP
ERCAP
V
SS
–0.3 to V
DD
+0.3
V
Voltage at SSCAP pin
SSCAP
SSCAP
V
SS
–0.3 to V
DD
+0.3
V
Voltage at SWO pin
SWO
SWO
V
SS
–0.3 to V
DD
+0.3
V
Voltage at I
SENSE
 pin
I
SENSE
I
SENSE
V
SS
–0.3 to V
DD
+0.3
V
Package allowable loss
P
D
P
D
300
MW
Ta
25˚C
Operating temperature
Topr
–30 to +85
˚C
Storage temperature
Tstg
–55 to +150
˚C
Soldering temperature and time
Tsol
260 · 10
˚C·S
Note :Any operation under conditions exceeding the above absolute maximum ratings may result in a malfunc-
tion or a permanent destruction.   When even an item is more than the rating, a temporary normal operation
is possible but with remarkably low reliability.   So, be sure to keep all items below the ratings.
comes to the V
SS
 level, and the output voltage is con-
trolled with the soft start circuit after the power off state
is released.   In the operating state, set the POFFX pin to
the V
DD
 level to operate it. The POFFX pin cannot be
operated in a open state. When the power off function is
not used, connect the POFFX pin to the V
DD
 pin.