Tektronix AFG3000 User Manual
Syntax and Commands
3-58
AFG3000 Series Arbitrary/Function Generators Reference Manual
[SOURce[1|2]]:FUNCtion:EFILe
This command sets or queries an EFILe name used as an output waveform. A file
name must be specified in the mass storage system. This command causes an error
if there is no file in the mass storage.
name must be specified in the mass storage system. This command causes an error
if there is no file in the mass storage.
Group
Source
Syntax
[SOURce[1|2]]:FUNCtion:EFILe <file_name>
[SOURce[1|2]]:FUNCtion:EFILe?
Arguments
<file_name>::=<string> specifies a file name in the mass storage system. The
<file_name> includes path. Path separators are forward slashes (/).
<file_name> includes path. Path separators are forward slashes (/).
Returns
<file_name>
Examples
SOURce1:FUNCtion:EFILe “SAMPLE1”
sets a file named “SAMPLE1” in the mass storage.
sets a file named “SAMPLE1” in the mass storage.
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry
This command sets or queries the symmetry of ramp waveform for the specified
channel.
channel.
Group
Source
Syntax
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry {<symmetry>|MINimum|MAXimum}
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry? {MINimum|MAXimum}
Arguments
<symmetry>::=<NR2>[<units>]
where
<NR2> is the symmetry.
<units>::=PCT
where
<NR2> is the symmetry.
<units>::=PCT
Returns
<symmetry>
Examples
SOURce1:FUNCtion:RAMP:SYMMetry 80.5
sets the symmetry of the CH 1 ramp waveform to 80.5 %.
sets the symmetry of the CH 1 ramp waveform to 80.5 %.