[SOURce[1|2]]:FUNCtion:EFILe
This command sets or queries an EFILe name used as an output waveform. A file 
name must be specified in the mass storage system. This command causes an error 
if there is no file in the mass storage.
Group
Source
Syntax
[SOURce[1|2]]:FUNCtion:EFILe <file_name>
[SOURce[1|2]]:FUNCtion:EFILe?
Arguments
<file_name>::=<string> specifies a file name in the mass storage system. The 
<file_name> includes path. Path separators are forward slashes (/). 
Returns
<file_name>
Examples
SOURce1:FUNCtion:EFILe “SAMPLE1”
sets a file named “SAMPLE1” in the mass storage.
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry
This command sets or queries the symmetry of ramp waveform for the specified 
channel.
Group
Source
Syntax
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry {<symmetry>|MINimum|MAXimum}
[SOURce[1|2]]:FUNCtion:RAMP:SYMMetry? {MINimum|MAXimum}
Arguments
<symmetry>::=<NR2>[<units>]
where
<NR2> is the symmetry.
<units>::=PCT
Returns
<symmetry>
Examples
SOURce1:FUNCtion:RAMP:SYMMetry 80.5