Siemens hipath 80 User Manual

Page of 258
beispiele.fm
A31003-O1010-M100-9-76A9, 05/05/2008
HiPath 8000 - OpenStage Family, Administration Manual
4-1
  
  
  
Examples and HowTos
Canonical Dialing
4
Examples and HowTos
4.1
Canonical Dialing
4.1.1
Canonical Dialing Settings
The following example shows settings suitable for the conversion of given dial strings to canon-
ical format. The example phone is located in Nottingham, UK.
Parameter
Example value Explanation
Local country code
44
International country code for the UK.
National prefix digit
0
Used in front of national codes when dialled 
without international prefix.
Local national code
115
Area code within the UK (here: Nottingham).
Minimum local number 
length
7
Minimum number of digits in a local PSTN 
number (e. g. 3335333 = 7 digits).
Local enterprise node
780
Prefix to access Nottingham numbers from 
within the Siemens network.
PSTN access code
9
Prefix to make an international call in the UK.
Operator codes
0, 7800
Set of numbers to access the local operators.
Emergency numbers
999, 555
Set of numbers to access emergency ser-
vices.
Initial extension digits
2, 3, 4, 5, 6, 8
1
st
 digits of numbers that are used for extensi-
on numbers on the local node.
Tabelle 4-1