Sub-Zero w422210 User Manual

Page of 8
Planning Information
Wolf Ventilation Recommendations
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
P R O   V E N T I L A T I O N   C F M R E C O M M E N D A T I O N S
Pro Low-Profile Wall Hoods
W302210I W362210(I) W422210
W482210
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
900
DF364 / R364 / SRT364 / RT364
900
900
RT362
900
900
DF484 / R484 / SRT484 / RT484
900
R482 / RT482
900
NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a
charbroiler or griddle.
Model numbers for dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops indicate width and number of surface
burners. Features such as a charbroiler, griddle and/or French Top will vary.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be
required for long duct runs.
P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S
Pro Low-Profile Wall Hoods
Blower Description
Blower Number
Wall Hood Models
600 CFM Internal*
Included with (I) Models
W302210I / W362210I
600 CFM Internal*
WBLOWER-60INT (807614)
W362210 / W422210
600 CFM In-Line*
BLOWER-60IL (808331)
W362210 / W422210 / W482210
600 CFM Remote
BLOWER-60REM (801640)
W362210 / W422210 / W482210
900 CFM Remote
BLOWER-90REM (801641)
W362210 / W422210 / W482210
*Vertical discharge with 8" (203) round duct. Remote blowers are adjustable discharge with 8" (203) round duct. NOTE: For optimal
performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle.
Wall hood models without decorative rail listed; blower options are the same for (R) models. Transition with backdraft damper included
with all wall hoods. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking
product. Always consult a qualified HVAC Engineer for specific applications.