36"
(914)
Sealed Burner Rangetop
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf
sealed burner rangetop to avoid any fires or
damage to adjacent cabinetry or kitchen equip-
ment. Follow the minimum clearances estab-
lished in the finished rough opening dimensions
as shown in the Installation illustration.
The platform for the rangetop must be 
3
/
4
"
(19) thick and include a cut-out at the right rear
for gas supply and electrical connections. The
platform must be level to ensure that the
cooking surface is level.
IMPORTANT NOTE: A minimum 5" (127) riser
is required when installing Model SRT366
against a combustible surface. A minimum 10"
(254) riser is required for charbroiler (C) or
griddle (G) models installed against a
combustible surface.
It is recommended that you use a Wolf Pro
wall or island ventilation hood or hood liner
with the Wolf sealed burner rangetop. Refer to
the Pro Ventilation section of our website,
wolfappliance.com.
The Wolf sealed burner rangetop requires a
110/120 V AC, 50/60 Hz electrical supply to
operate the electronic ignition system. The
power supply cord is equipped with a 3-prong,
grounded plug for protection against shock
hazard. The service should have its own 15
amp circuit breaker. Locate electrical and gas
supply within the shaded area shown in the
Installation illustration.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf sealed burner rangetops are designed
to operate on natural gas at 5" (12.5 mb) WC
(water column) pressure or LP (propane) gas at
10" (25 mb) WC pressure. The minimum line
pressure for natural gas is 7" (17.5 mb) WC and
11" (27.4 mb) WC for LP gas. The maximum
gas supply pressure to the regulator should
never exceed 14" (34.9 mb) WC; .5 psi (3.5
kPa).
If local codes permit, a certified, 3' (.9 m)
long, 
1
/
2
" or 
3
/
4
" ID flexible metal appliance
connector is recommended for connecting the
rangetop to the gas supply line.  
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the
rangetop in an accessible location. 
Wolf sealed burner rangetops using natural
gas will operate up to an altitude of 8,000'
(2438 m) without any adjustment. Natural gas
and LP gas installations from 8,000' (2438 m)
to 11,000' (3353 m) need the high altitude
conversion kit. Contact your Wolf dealer for
details. To obtain local dealer information, 
visit the Locator section of our website, 
wolfappliance.com.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.