 6.0  OPERATION 
 
• 
The basic weighing functions are same for both the scales- local 
and remote.  However the number of weighing divisions may be 
less on the remote scale dependant on the total capacity of the 
load cell/s used. 
 
• 
Each scale (local or remote) has the ability to count parts based 
on the current unit weight. This is best obtained by performing a 
sample on the local scale which may have the best sensitivity. 
Then the scale can be switched to the remote where large 
quantities can be counted. 
 
• 
Each scale has a separate tare value that can be entered through 
the keypad or by placing a weight on the platform and pressing 
the [Tare/Zero] key.  The tare value for each scale is retained as 
the user switches between the remote and local scales. 
 
• 
Either scale can be used to determine a unit weight. 
 
• 
When the scale is switched from local to remote, a clear display 
will be shown to identify the change and the scales will count 
based on the tare and unit weight currently in use for the scale 
selected.  Display for the change is: 
 
c h A n g E
” ”
L o c A L
“ 
and 
c h A n g E
” ”
r e m o t E
 “ 
 
The display will be based on the 7 segment interpretations, some 
of the letters are shown later. 
 
•  The switch from local scale to remote scale should be possible at 
any time by pressing the [Local/Rem] key or if the user enables 
the function it can happen anytime the weight on the remote scale 
changes from negative value or zero to a positive value greater 
than 50d.  
 
 
NOTE: For frequently used items, counting is made easier by using PLU 
numbers (Product Look Up). Up to 100 PLU’s can be stored and 
recalled. See section 6.4 on PLU for details. Place the item on the pan 
and enter using the keypad “
PLUxx” (where xx is the PLU number 
associated with that item). The scale will display the Total Weight, Unit 
weight and the Count of the item in the respective windows.
 
 
© Adam Equipment Company 2007