Tascam DA-78HR User Manual

Page of 78
7 - Advanced operations
 TASCAM DA-78HR 
42
2
Use the   and  keys to change the value 
(maximum +6.0%, minimum –6.0%, in 0.1% 
steps).
Reset the value to 0.00% by pressing and hold-
ing either of the 
 or  keys, and pressing the 
other.
3
Press the 
SHIFT
 key to turn off the setting 
mode. The 
VARI SPEED
 indicator will continue 
to be lit, showing that varispeed is currently 
enabled.
4
Turn off varispeed (when the 
VARI SPEED
 
indicator is lit) by pressing the 
VARI SPEED
 
key to turn the indicator off.
NOTE
The VARI SPEED indicator will light whenever the 
varispeed is enabled, even if the speed is set to 
0.0%.
Playback and recording will now take place at the 
new speed.
7.7 Shuttle operations
The shuttle key, indicator and knob are used to simu-
late the “rock and roll” location method on open-reel 
tape decks, allowing you to locate a point on tape 
through audible cues.
As the knob is moved from the center detented posi-
tion, the shuttle speed becomes higher.
The variation in speed is not continuous; but as you 
turn the knob from the center position, the shuttle 
speed changes, following these values (relative to 
normal speed): 0.25, 0.5, 1.0, 2.0, 4.0, 8.0. The 1.0 
speed is only available when shuttling in the forward 
direction.
Shuttle operations are only possible when the 
SHUT-
TLE
 indicator is lit (press the 
SHUTTLE
 switch).
If the 
SHUTTLE
 knob remains untouched at the 
center 
position for 10 seconds, the shuttle mode is disabled, 
and the indicator goes off.
7.7.1 Shuttle monitoring
This is also covered in 6.3, “Shuttle monitor”. The 
default behavior of the DA-78HR is that when shut-
tling the tape, you monitor off the recorded tape.
NOTE
When monitoring in shuttle mode, the monitor signal 
is attenuated by 12 dB (to avoid possible damage to 
ears and speakers ).
When 
AUTO MON 
is on
,
 the monitoring of any 
armed tracks will be off-tape, unless the 
SHTL MON
 
is on, in which case, the monitoring of armed tracks 
will be source input. The monitoring of all other 
(unarmed) tracks can still be switched on a track-by-
track basis using the tracks’
 INPUT MONITOR
 
switches.
The 
SHTL MON
 key is only enabled when 
AUTO 
MON
 is on. When 
AUTO MON
 is off, it has no effect.
7.7.2 Shuttle muting
As explained above, shuttling the tape will usually 
allow off-tape monitoring. However, there may be 
times when you will want to mute all off-tape signals 
when shuttling. This procedure is described in 6.4, 
“Shuttle muting”.
7.8 Meter modes
The DA-78HR peak bargraph meters can be custom-
ized to suit your working preferences. Both the peak 
hold time and the “ballistics” of the meters can be 
adjusted.
7.8.1 Peak hold time
1
Press the 
SHIFT
 key so that the 
SHIFT
 indicator 
is flashing, and press the 
MENU
 key until the 
display shows 
SYSTEM--
 (
SYSTEM--
).
2
Press the 
SUB MENU
 key until the display 
shows 
PK. H. LD. ;;
 (
PK HLD xx—
peak hold) 
with the current value for this setting.
3
Use the  and  keys to change the value 
between 
0 and 9 seconds or CNT (
CNT
—con-
tinue—which will permanently  display  the 
maximum peak signal level. This can be useful 
if you are doing a “dry run” rehearsal, but you 
cannot keep your eyes on the meters all the 
time that the rehearsal is going on).
To turn off the peak hold display if 
CNT
 
has 
been set, change the peak hold value to 
0
 sec-
onds and the meter segments will “drop back”.
7.8.2 Meter ballistics
Use a  similar process  to change  the “fall-back”  bal-
listics of the peak meters. You cannot change the rise 
time of the meters, which are fixed with peak meter 
characteristics.
1
Press the 
SHIFT
 key so that the 
SHIFT
 indicator 
is flashing, and press the 
MENU
 key until the 
display shows 
SYSTEM--
 (
SYSTEM--
).