Tascam DA-78HR User Manual

Page of 78
 TASCAM DA-78HR 
47
8 - Synchronization with other DTRS units
This section describes the techniques and methods to 
be followed when the DA-78HR is linked to other 
DTRS units (e.g. TASCAM DA-98, DA-38, DA-88 
and of course other DA-78HR units).
Up to 16 DTRS units can be linked, for a total of 128 
digital tracks.
If you are connecting DTRS units of different types 
to the DA-78HR, use the DA-78HR or a DA-98 as 
the master unit and the other units as slave units.
8.1 Synchronization connections
The cable  to be used  when connecting the DA-78HR 
to other DTRS units for synchronization purposes 
should be a PW-88S cable. This is 1 meter (3 ft.) 
long. If you require a longer cable, please consult 
your TASCAM  dealer.
NOTE
S
Be sure to use only the optional PW-88S sync cables. The 
use of any other cables  could damage the DA-78HR.
Be sure to connect the ter mination plug to the last slave’s 
SYNC OUT connector, or else incorrect functions may 
occur.
Turn on  all the DTRS units  in your system,  regardless of 
whether you actually use all of them. A unit or units turned 
off will make synchronization impossible.
To synchronize multiple  DTRS  units,  use  a pre-for matted 
tape in  the  master  unit, and  also  in the slave units. Since 
the DTRS system uses  ABS time  to  achieve  synchroniza-
tion, it is impossible to synchronize using tapes without 
ABS  time recorded on  them.
To synchronize multiple DTRS units, all the tapes in 
each unit must be formatted at the same sampling 
rate, or synchronization is impossible.
The synchronization connections form a “daisy-
chain”, with the master unit at the head of the chain, 
and the last slave at the tail.
Connections are made from the 
SYNC OUT
 of one 
unit to the 
REMOTE IN/SYNC IN 
of the next. This 
connection also carries the word clock between the 
DTRS units. Slave units will automatically take their 
clock through this, as shown by the front panel 
CLOCK
 indicators, neither of which will be lit.
There are exceptional circumstances when indepen-
dent clocks may be necessary. See 8.6, “Individual 
clock mode”
 for details.
NOTE
Always make and break all connections with the 
power to all units in the chain turned OFF.
8.2 Machine ID and master/slave 
settings
Each DTRS unit in the chain must be assigned a 
machine ID. The unit at the head of the chain (the 
master) should have ID  number  1. 
Though not strictly necessary, we suggest that IDs 
are  assigned in  a consecutive sequential  order  from 
the head of the chain.
8.2.1 Differences between DTRS models
The DA-78HR, DA-98 and DA-38 use machine IDs 
that are set by software (the machine must be turned 
on for the ID to be set). The values for the IDs of 
these models start at “1” and go up to “16”. 
The switch on the back of the DA-88 is only opera-
tive when the unit is turned off. It is marked from “0” 
through “F”. 
When including DA-88s and DA-78HRs in the same 
chain, add 1 to the number shown on the DA-88’s 
rear panel machine ID switch to make the DA-88’s 
machine ID match the series of the DA-78HR (and 
DA-98 and DA-38) IDs. Any DA-88 whose Machine 
ID is not 1 (the switch has been set to a value other 
than 0) will show its Slave ID briefly at power-on.
Therefore, for a chain of three units; a DA-78HR as 
master, with a DA-98 and DA-88 as slaves, the 
machines’ IDs should be set as follows:
It therefore makes sense to set the machine IDs of all 
DA-88s in the chain first, immediately after connec-
tions have been made with the power off, and then 
turn on power to all units before setting the machine 
IDs of all DA-78HRs, DA-98s and DA-38s in the 
chain.
NOTE
When you set the machine IDs, you can set the ID of 
any machine first, but we recommend doing this in a 
Unit
ID
 as 
sh
o
w
n
R
eal
” I
D
How the ID  is 
set
P
o
w
e
r o
n
 or
 of
w
h
en
 I
D
 i
s
 set
DA-78HR
1
1
Tape counter 
menu system
ON
DA-98
2
2
Menu system
ON
DA-88
2
3
Rotary switch on 
rear panel
OFF