ACS 1000x User Manual

Page of 45
1000 Series Granulators 
Chapter 5: Maintenance 
24 of 45 
Chapter 5:  Maintenance 
5-1  Preventative Maintenance Schedule 
Check 
Frequency 
Knife clearance 
Weekly 
Knife retaining screws for tightness 
Weekly 
Shield retaining screws for tightness  
Weekly 
Screen cradle screws for tightness 
Weekly 
Lubrication of drive motor bearings  
Monthly 
Screen Wear 
Monthly 
Belt tension 
Monthly 
Hopper and cutting chamber screws are tight 
Monthly 
 
5-2  Testing the Interlock Switch 
The cutting chamber interlock switch ensures that the granulator cannot be running when the 
cutting chamber or screen cradle are open.  When disengaged, the interlocks open the 
electrical control circuit to the motor and prevent the machine from running. 
To test the interlock switch, retract the interlock actuator screw by turning it 
counterclockwise. Make sure that the end of the actuator screw is visible and clear of any 
contact. The granulator should stop. If the granulator does not stop, the interlock is not 
working. If the interlock does not work, the complete mechanism, including the switch, must 
be removed and disassembled to determine the cause of the malfunction.