14.5.2.6
Port x MAC Receive 128 to 255 Byte Count Register (MAC_RX_128_TO_255_CNT_x)
This register provides a counter of received packets between the size of 128 to 255 bytes. The counter
is cleared upon being read.
Note:
A bad packet is defined as a packet that has an FCS or Symbol error. For this counter, a packet
that is not an integral number of bytes is rounded down to the nearest byte.
Register #:
Port0: 0413h
Size:
32 bits
Port1: 0813h
Port2: 0C13h
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
RX 128 to 255 Bytes
Count of packets (including bad packets) that have between 128 and 255 
bytes.
Note:
This counter will stop at its maximum value of FFFF_FFFFh. 
Minimum rollover time at 100Mbps is approximately 848 hours.
RC