14.5.2.10
Port x MAC Receive Oversize Count Register (MAC_RX_OVRSZE_CNT_x)
This register provides a counter of received packets with a size greater than the maximum byte size.
The counter is cleared upon being read.
Note:
For this counter, a packet with the maximum number of bytes that is not an integral number of
bytes (e.g. a 1518 1/2 byte packet) is not considered oversize.
Register #:
Port0: 0417h
Size:
32 bits
Port1: 0817h
Port2: 0C17h
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
RX Oversize
Count of packets that have more than the maximum allowable number of 
bytes and a valid FCS. The max number of bytes is 1518 for untagged 
packets and 1522 for tagged packets. If Jumbo2K (bit 3) is set in the 
of bytes is 2048.
Note:
This counter will stop at its maximum value of FFFF_FFFFh. 
Minimum rollover time at 100Mbps is approximately 8813 hours.
RC