SMSC LAN9311 User Manual
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
Revision 1.4 (08-19-08)
356
SMSC LAN9311/LAN9311i
DATASHEET
14.5.2.33
Port x MAC Transmit 1024 to Max Byte Count Register (MAC_TX_1024_TO_MAX_CNT_x)
This register provides a counter of transmitted packets between the size of 1024 to the maximum
allowable number bytes. The counter is cleared upon being read.
allowable number bytes. The counter is cleared upon being read.
Register #:
Port0: 0459h
Size:
32 bits
Port1: 0859h
Port2: 0C59h
Port2: 0C59h
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
TX 1024 to Max Bytes
Count of packets that have more than 1024 bytes.
Count of packets that have more than 1024 bytes.
Note:
This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 5979 hours.
Minimum rollover time at 100Mbps is approximately 5979 hours.
RC
00000000h