SPT wa-1400e User Manual

Page of 20
SPECIFICATION
Model no. 
WA-1400E
WA-1410E
WA-1400H
WA-1410H
Cooling capacity 
14000 BTU/hr 
14000 BTU/hr 
Heating capacity 
-
14000 BTU/hr 
Power/Ampere
consumption for cooling* 
1250W/ 11.0A
1250W/ 11.0A 
Power/Ampere
consumption for heating*
-
1250W/ 11.0A 
Air volume (max. speed) 
580m
3
/h 580m
3
/h
Humidity removal capacity
53.9 L/day 
53.9 L/day 
Recommended room size 
500sq.ft. 
500sq.ft. 
Power supply 
115V/60Hz/1phase
Compressor Rotary 
Refrigerant
R-22
Refrigerant load* 
680 g 
Fan speed 
3
Timer
1~ 24 hours 
Working temperature 
Cooling: 64.4
o
 F~ 110
o
F
Heating: 41
o
 F~ 80.6
o
F
Thermostat
62
 o
 F ~ 90
 o
 F 
Exhaust pipe 
5 in x 59 in 
Net Weight 
86 lbs. 
Dimension
14 x 21 x 30 in (WxDxH) 
REMARK:
1. The data marked with '*' may vary for technical reasons. 
2. Measuring condition for above is:  Cooling – RT80.6
 o
F, RH60% 
Heating – RT68
 o
F, RH60% 
*RT means room temperature 
*RH means room humidity. 
• 
Un-insulated rooms such as sunrooms, garages, or attics should be less 
than 500sq.ft.
• 
The following may effect the unit in reaching your set tempearature: 
Outside Temperature, Room Size, Ceiling Height, Room Insulation, 
Number of people in the room, Direct Sunlight and Source of Heat.
3