DATASHEET
17.6
ALTINT
Alternate Interrupt Mode.
0 = Primary interrupt system enabled (Default).
1 = Alternate interrupt system enabled.
Se
.
RW
0
17.5:4
Reserved
Write as 0, ignore on read.
RW
00
17.3
PHYADBP
1 = PHY disregards PHY address in SMI access 
write.
RW
0
17.2
Force
Good Link Status
0 = normal operation;
1 = force 100TX- link active;
Note:
This bit should be set only during lab testing
RW
0
17.1
ENERGYON
ENERGYON – indicates whether energy is detected 
on the line (see 
); it goes to “0” if no valid 
energy is detected within 256ms. Reset to “1” by 
hardware reset, unaffected by SW reset.
RO
X
17.0
Reserved
Write as 0. Ignore on read.
RW
0
Table 5.30  Register 18 - Special Modes
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
18.15
Reserved
Write as 0, ignore on read.
RW
0
18.14
MIIMODE
MII Mode: set the mode of the digital interface, as 
described in 
:
0 – MII interface.
1 – RMII interface
RW, 
NASR
X
18.13:8
Reserved
Write as 0, ignore on read.
RW, 
NASR
000000
18.7:5
MODE
Transceiver Mode of operation. Refer to 
more details.
RW, 
NASR
XXX
18.4:0
PHYAD
PHY Address.
The PHY Address is used for the SMI address and for 
the initialization of the Cipher (Scrambler) key. Refer 
to 
 for more details.
RW, 
NASR
PHYAD
Table 5.31  Register 26 - Symbol Error Counter
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
26.15:0
Sym_Err_Cnt
100Base-TX receiver-based error register that 
increments when an invalid code symbol is received 
including IDLE symbols. The counter is incremented 
only once per packet, even when the received packet 
contains more than one symbol error. The 16-bit 
register counts up to 65,536 (2
16
) and rolls over to 0 
if incremented beyond that value. This register is 
cleared on reset, but is not cleared by reading the 
register. It does not increment in 10Base-T mode.
RO
0
Table 5.29  Register 17 - Mode Control/Status (continued) 
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT