Drying Hopper 
Removing the Rust Inhibitor 
Rust preventative has been applied to internal unfinished surfaces. Remove rust inhibitor before 
using the drying hopper. 
Using a non-water based degreasing agent, clean all inside surfaces of the drying hopper. Allow 
components to dry thoroughly.    
Inspect the inside of the drying hopper for loose connections, foreign objects, or a blocked 
diffuser. 
Air Trap Considerations 
The air trap assembly in the top of the drying hopper prevents ambient air from contaminating the 
material being dried. 
  Keep the material level at the mid point of the air trap for maximum efficiency. 
  Use a hopper loader or vacuum conveying system to maintain the proper material level. 
 
3-7  
Positioning Your Dryer 
For the dryer work function properly it is critical to place the process air thermocouples on the 
drying hopper inlet and outlet. These devices accurately monitor the air temperature entering and 
leaving the drying hopper, the value of which is used by the control to maintain the process 
temperature set point. Compression fittings are required to hold the thermocouple in place so that 
the tip is approximately in the center of the tube as shown.
 
 
Air Inlet 
Air Return 
This photo demonstrates the proper 
location of the thermocouple inside 
the air inlet and return tubes. 
Adapter (if required) 
1/8” NPT to BSPT
 1/8” 
Compression fitting 
Thermocouple 
The locations of 
the inlet and 
return will vary 
on different 
drying hoppers. 
 