Chapter 7
Diagnostics and Troubleshooting
123
5. When POST is completed, disconnect the
tip
window as follows:
a. Open a shell window.
b. Type
ps -a
to view the active
tip
line and process ID (PID) number.
c. Type the following to kill the
tip
hardwire process.
Verifying the Baud Rate
To verify the baud rate between the Sun Enterprise 220R server and a terminal or
another Sun system monitor:
1. Open a shell window.
2. Type
eeprom
.
3. Verify the following serial port default settings as follows:
Note –
Ensure that the settings are consistent with TTY-type terminal or system
monitor settings.
What to Do
Ensure that the front panel keyswitch is in the Standby position.
For descriptions of the keyswitch settings, see “About the Status and Control Panel”on page 7.
You can initialize POST one of two ways.
By setting the
diag-switch?
to
true
and the
diag-level
to
max
or
min
,
followed by power cycling the system unit.
By simultaneously pressing the keyboard Stop and D keys while power is applied
to the system unit.
kill -9
<Process ID (PID)  Number>
ttyb-mode = 9600,8,n,1
ttya-mode = 9600,8,n,1