29
Installation
F232058
Steam Requirements
(Steam Heat Option Only)
For machines equipped with optional steam 
heat, install piping in accordance with 
approved commercial steam practices. Steam 
requirements are shown in the table below. 
Note: 
Failure to install the supplied steam 
filter may void the warranty.
Never touch internal or external steam 
pipes, connections, or components. These 
surfaces can be extremely hot and will 
cause severe burns. The steam must be 
turned off and the pipe, connections, and 
components allowed to cool before the pipe 
can be touched.
SW014
WARNING
Steam Supply Information
Steam inlet connection, in. (mm)
1/2 (DN13)
Number of steam inlets
1
Recommended pressure, psi (bar)
30 – 80 (2.0 – 5.5)
Maximum pressure, psi (bar)
80 (5.4)