Alliance Laundry Systems sf50pv User Manual

Page of 119
Installation
40
F232058
Note: 
Ensure cables are routed safely and 
away from potential hazards. Use wire ties, 
included with the kit, to secure cabling. 
Provide some slack for repositioning of the 
canister/filter/pump assembly after electrical 
connections are made.
d. One the 35- and 50-pound models
route the 2-conductor and 4-conductor 
cable through the two PG 13.5 strain 
reliefs installed in step b. See Figure 23. 
On the 85-pound model, route both the 
2-conductor cable and the 4-conductor 
cable through the PG 21 strain relief as 
shown in Figure 24.
Note: 
Ensure strain reliefs are tightened 
securely around the cable.
e. Connect red wire in the 2-conductor 
cable from the canister/filter/pump 
assembly to terminal A2 of the pump 
contactor. See Figure 23.
f. Extend 2-conductor cable #223, which 
is capped in the rear control module. 
Connect red wire of #223 to the black 
wire of the 2-conductor cable from the 
canister/filter/pump assembly.
g. Connect the black wire of the #223 
cable to terminal A1 of the pump 
contactor.
h. Connect L1, L2, and L3 from the circuit 
breaker to the input side of the mains 
contactor, using the 18GA gray wire, 
included in the kit.
i. Connect the 4-conductor cable wires to 
the pump contactor terminals as 
follows: wire No. 1 to terminal T1, wire 
No. 2 to T2, and wire No. 3 to T3. Wire 
No. 4 (green-yellow) must be 
connected to the chassis ground.
Note: 
If pump motor rotation is incorrect 
during the control function test, swap any two 
wires at terminals T1, T2, or T3 of pump 
contactor. See Figure 26 for correct motor 
rotation direction.
7. Verifying electrical connections:
a. Secure any loose or dangling wires, 
using the wire ties.
b. Verify that all connections are secure 
and routed properly.
8. Reassembling machine panels:
a. Reassemble rear panel and right front 
panel.
b. Reinstall rear control module cover.
9. Install water recirculation piping:
a. Remove the cap on the recirculation 
inlet on top of the shell. See
Figure 20.
b. Attach the 1 1/2-inch black hose 
connector (no clamp grooves), included 
in the kit, between the shell 
recirculation inlet and the adapter plate.
c. Attach upper recirculation pipe to the 
hose connector at the recirculation 
adapter plate on the rear of the washer-
extractor. See Figure 26.