Tascam RC-898 User Manual

Page of 76
Section 2.2 - Rear Panel  
2-6 
[45]
DIP switches (1 & 2)
The two DIP switches are both on when in the 
down position. As shipped from the factory, 
switch 1 is off (up) and switch 2 is on (dow), and 
you probably will not need to change them.
However, when a passive device is connected to 
the 
EXT 1
 connector and power is not provided 
from the device to the tally supply pin, this switch 
1 (
TALLY POWER
) should be set to the on 
(down) position, allowing the RC-898 to use its 
own power for this purpose.
Switch 2, 
GND LIFT
 (ground lift) controls the 
isolation of the ground of the RC-848/DTRS sys-
tem from the ground of devices attached to the 
EXT 1
 and 
EXT 2
 ports. Usually this switch is in 
the on (down) position, but you may need to turn it 
off (up) if your system suffers from hum prob-
lems. However, a full discussion of ground loops 
and their associated problems is outside the scope 
of this manual, and we recommend that you con-
sult one of the many reference works on this sub-
ject if necessary.
[46]
Contrast
This control alters the contrast on the backlit LCD 
display screen [11]. Use it to set the screen so that 
it is easily visible from your preferred viewing 
angle.