Promise Technology EX8650 User Manual

Page of 232
Chapter 5: Management with WebPAM PRO
139
Rebuilding a Disk Array
When you rebuild a disk array, you are actually rebuilding the data on a 
replacement physical drive.
Rebuilding Automatically
Normally, a disk array would rebuild itself using a hot disk drive, after going 
Critical. However, if the Auto Rebuild function is disabled or no spare drives are 
available, you must initiate the procedure.
To create a spare drive, see “Creating a Spare Drive” on page 150.
For more information, see “Hot Spare Drive(s)” on page 175.
Rebuilding Manually
If a physical drive has failed, identify and replace the drive, then rebuild the disk 
array as described below:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click the Disk Arrays 
 icon. 
3.
Click the Disk Array   icon. 
If there are multiple disk arrays, choose the icon with the yellow !. 
4.
From the dropdown menu on the Background Activity tab, choose Start 
Rebuild
5.
Choose Source physical drive.
This is a remaining functional physical drive in the disk array. 
6.
Choose the Target physical drive.
This is the replacement physical drive. 
7.
Click the Submit button. 
The Disk Array Background Activity tab will show the rebuild the replacement 
(target) physical drive. Depending the size of the physical disk involved, this 
process will take some time.
To view more information, click the Rebuild on PDx link.