Chapter 5: Management with WebPAM PRO
141
Transitioning a Disk Array
Transition is the process of replacing a revertible spare drive that is currently part 
of a disk array with an unconfigured physical drive or a non-revertible spare. The 
revertible spare drive returns to its original status. For more information, see 
“Transition” on page 185.
In order to run the Transition function:
The spare drive must be Revertible.
You must specify an unconfigured physical drive of the same or larger 
capacity to replace the revertible spare drive.
To run Transition:
1.
Click the Subsystem 
 icon in Tree View. 
2.
From the dropdown menu on the Background Activities tab, choose Start 
Transition
3.
Choose an unconfigured physical drive from the list of available drives. 
After Transition is completed, refresh the screen. The revertible spare drive will 
be listed under the Spare Drives   icon and the disk array’s operational status 
will show OK.
Preparing a Disk Array for Transport 
To prepare a disk array for transport: 
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click the Disk Arrays 
 icon. 
3.
Click the Disk Array   icon. 
4.
Click the Transport tab in Management View. 
5.
Click the Submit button. 
6.
In the confirmation box, type the word confirm in the field provided. 
Important
Before you can use this feature:
There must be a dedicated spare disk drive assigned to this 
disk array.
The disk array’s Operational Status must be OK.