Polycom 7000 User Manual
NetEngine IAD User Guide
Bridge Configuration
136
3. If more than one interface is configured on the selected port, the IAD
displays a list of interfaces:
Port
DLCI
Encapsulation
1
18
Proprietary Voice DLCI
Type the number of the port.
4. The IAD displays a prompt:
Enter Priority for Slot 2, Port 1 (0..255):
Type the priority value and press Enter.
5. The IAD updates the configuration and displays the Bridge
Configuration menu.
6. Repeat these steps for each port on which you want to set the priority.
7. Continue with other configuration tasks, or press Escape to return to
7. Continue with other configuration tasks, or press Escape to return to
the Bridge Configuration menu.
8. Reset the IAD (page
) when you finish bridge configuration.
Config-
uring
Spanning
Tree Hello
Time
uring
Spanning
Tree Hello
Time
To set the Spanning Tree hello time (a value between 1 and 10 seconds—
default 2), follow these steps:
default 2), follow these steps:
1. Type
H
on the Bridge Configuration menu to select Configure Spanning
Tree Hello Time.
2. The IAD displays the following prompt:
Enter Bridge Hello Time(1..10): (2)
Type the priority value and press Enter.
3. The IAD updates the configuration.
4. Press any key to return to the Bridge Configuration menu and continue
4. Press any key to return to the Bridge Configuration menu and continue
with other configuration tasks.
5. Reset the IAD (page
) when you finish bridge configuration.
Config-
uring
Spanning
Tree
Maximum
Age
uring
Spanning
Tree
Maximum
Age
To set the Spanning Tree maximum age, (a value between 6-40
seconds—default 20), follow these steps:
seconds—default 20), follow these steps:
1. Type
S
on the Bridge Configuration menu to select Configure Spanning
Tree Max Age.
2. The IAD displays the following prompt:
Enter Spanning Tree Max Age (6..40): (20)
Type the maximum age value and press Enter.
3. The IAD updates the configuration.
4. Press any key to return to the Bridge Configuration menu and continue
4. Press any key to return to the Bridge Configuration menu and continue
with other configuration tasks.
5. Reset the IAD (page
) when you finish bridge configuration.