Polycom 7000 User Manual

Page of 323
NetEngine IAD User Guide
Voice Path Configuration
144
Configuring Start Mode on an Individual Port
1. Type 
4
 on the Start Mode Selection menu to select Configure 
Individual Port.
2. For each port, the IAD displays the following prompt:
Port 1 [Loop] (1=Lp/2=Grnd/3=DID Wnk/4=E&M Wnk/5=Raw 
ABCD/0(or Enter)=NoChange):
3. Type one of the following options for each port:
1—Loop Start
2—Ground Start
3—DID Wnk
4—E&M Wnk
5—RAW ABCD
0 or Enter—no change
4. When you’ve updated each port, Press Enter a final time.
5. The IAD updates the settings and saves the configuration.
6. Press any key to return to the Start Mode Selection menu. Press 
Escape to continue with other voice path configuration.
7. Reset the IAD (page
when you finish voice path configuration.
Setting 
SLIC 
Control 
Mode
To set SLIC control mode (for POTS only), type 
T
 to display the SLIC 
Control Mode Selection menu:
Figure 7–5.  SLIC Control Mode Selection Menu 
Type the option of the control mode to set.
1. The IAD saves the mode you’ve selected and displays the menu.
2. Press Escape to return to the Voice Configuration menu and continue 
with other voice path configuration.
3. Reset the IAD (page
when you finish voice path configuration. 
*******************************************
SLIC Control Mode Selection
*******************************************
Current Control Mode = AUTO Control Mode
A. AUTO Control Mode
B. MANUAL Control Mode
 
NOTE
Voice gateway applications, such as CopperCom or 
JetStream, overrides the value set by this command.