Polycom spectralink jpi300 User Manual

Page of 68
Site Preparation 
PN: 1725-36122-001_M.doc 
29
When wiring multiple power pairs, use the following table as a guide. 
Pair 
Function 
Pin #s 
1 Data 1,2 
2 PWR 
1 7,8 
3 PWR 
2 4,5 
4 PWR 
3 6,3 
Power pairs are polarity sensitive; pins 7, 4, and 6 must be the same 
polarity. 
Prepare Demarc Blocks 
Interface Modules are designed to operate with a specific interface to 
the telephone system: two-wire digital or analog, or four-wire digital 
(future release). The number of demarcation blocks required for the 
system depends on the number and type of Interface Modules to be 
installed. 
Interface Type 
Interface 
Module  
Part Number 
Wire 
Pairs 
# Blocks 
Analog POTS 
CPA316 
Universal (Comdial, DEFINITY, 
Meridian 1, Norstar, Rolm) 
CPU316 1  1 
Four-wire digital 
CPF316 
Mitel (DNIC) 
CPM316 
Panasonic CPP316 
 
 
The CPU316 and CPM316 Interface Modules are intended only for 
connection to the isolated-side of an on-premise PBX. These 
interfaces are intended to connect to digital PBX ports that provide 
signals of 5Vp-p (max) AC component and some PBXs providing a 
48Vdc offset. 
Base Station wiring is the same for all Interface Modules. 
Based on the number and type of interfaces in the system, determine 
the number of 25-pair cables required to connect line ports and Base 
Stations to the demarcation blocks. The diagrams which follow 
provide an overview of the connections.