The Front Panel of the SpectraLink 6100 MCU 
The MCU’s front panel contains the connections to the telephone 
system, switches to control system administration, and status LEDs. 
 
  1.  STEP button: Selects a specific line or Base Station 
during registration process.  
  2.  Mode switch: Selects the mode of operation for the 
SpectraLink 6100 MCU.  
 ADMIN: Administration mode, used to set up system 
features to match features on the telephone system. 
 NORMAL: Normal mode, used during day-to-day 
operations.  
 REGISTER: Registration mode, used to add or delete 
handsets and Base Stations.  
  3.  DEL/ENTER button: Removes a registered handset from 
the system. 
  4.  IPC IN port: Used to connect preceding MCUs in a multi-
MCU configuration.  
  5.  IPC OUT port: Used to connect sequential MCUs in a 
multi-MCU configuration or to connect to an Open 
Applications Interface (OAI) Telephony Gateway.  
  6.  ERROR LED: Flashes when the system has detected an 
error. When flashing, check the STATUS LEDs for an error 
code.  
  7.  STATUS LEDs: Indicate system error messages and 
status. See SpectraLink 6100 MCU: Installation and 
Operation
 for more information.  
  8.  LINE LEDs: Indicate the line status of each handset: 
ringing, in-use or not active.  
  9.  BASE STN LEDs: Indicate the status of each Base 
Station. 
10.  CONN A or B: RJ-21 connector to the cross-connect 
demarc block. Connector B is supplied and used only 
with four-wire digital interface. 
11.  PWR jack: Connects to the AC adapter to supply power 
to the system.  
CAUTION
: Use only the provided Class II AC Adapter 
with output 24V DC, 1A. 
12.  Grounding lug: For use on the analog interface MCU 
(SCA-5XX).