Philips th-37pr10u User Manual

Page of 48
36
Options 
On 
Weekly Command Timer 
Onscreen display 
Off 
Initial INPUT 
1/3 
 
Maximum VOL level 
Initial VOL level 
Button lock 
INPUT lock 
Advanced PIP 
Remocon User level 
Off 
Off 
Off 
Off 
Off 
Off 
Options Adjustments
Item
Effect Adjustments
Initial VOL 
level
Off
On
Press 
 button to adjust the volume when the unit is turned on.
Off 
 On
Off: 
Sets normal volume.
On: 
Sets your preferred volume.
Notes:
• When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.
• You can hear the changed volume regardless of your volume setting before opening the options menu if you 
adjust the volume when “Initial VOL level” is “On” and cursor is on the menu.
Maximum VOL 
level
Off
On
Press 
 button to adjust the maximum volume.
Off 
 On
Off: 
Sets auto maximum volume.
On: 
Sets your preferred maximum volume.
Notes:
• If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically 
becomes the same as the “Maximum VOL level”.
• The volume display can go up to 63 regardless of the settings.
• You can hear the changed volume regardless of your volume setting before opening the options menu if you 
adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu.
INPUT lock
Off 
 PC 
 INPUT1 
 INPUT2 
 INPUT3
Locks the input switch operation.
Notes:
• Only the adjusted signal is displayed (see page 13).
• Signal can be displayed when the Terminal board is installed.
• Input switch can be used when this is set to “Off”.
• In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input 
in the single screen display mode.
• When a dual input terminal board is attached, A or B is displayed depending on the selected input 
signal. (Ex. INPUT1A, INPUT1B)
Button lock
Off 
 MENU&ENTER 
 On 
Off: 
All the buttons at the bottom of the main unit can be used.
MENU & ENTER: Locks 
MENU
 and 
ENTER/
 buttons on bottom face of main unit.
On: 
Locks all the button on bottom face of main unit.
Sets Button lock with the unit buttons in the following procedure.
Off:  
Press   four times
→Press 
INPUT
 four times
→Press   four times→Press 
ENTER/
MENU & ENTER:  
Press 
ENTER/
 four times
→Press   four times→Press 
INPUT
 four times
→Press 
ENTER/
On:  
Press   four times
→Press 
ENTER/
 four times
→Press   four times→Press 
ENTER/
Remocon 
User level
Off 
 User1 
 User2 
 User3 
Off: 
You can use all of the buttons on the remote control.
User1: You can only use 
,  , 
 buttons on the remote control.
User2: You can only use 
, buttons on the remote control.
User3: Locks all the buttons on remote control.
Advanced PIP
Off
On
Off: 
Sets normal two screen display mode (see page 20).
On: 
Sets Advanced PIP mode (see page 21).
Notes:
• When “INPUT lock” is “On”, you cannot use all the two screen display functions.
• 
 buttons are unavailable during Advanced PIP mode operation.