Pelco SPECTRA III SE User Manual

Page of 4
Spectra III
 Series
Spectra III
 SE Series
Switch Settings Manual
C2447M (2/02)
®
Table A.
Switch Settings for SW3
Baud Rate Selection Switch
Table B.
Switch Settings for SW1
P-Type Control
NOTE: For Coaxitron
controls, SW1 is not
used; set all switches
OFF. For D-type control
systems, refer to Table C.
Tabla A.
Posiciones del
conmutador SW3
Conmutador de selección
de velocidad en baudios
Tabela A.
Configurações de Chave
para SW3
Chave de seleção de
taxa de bauds
Tabla B.
Posiciones del
conmutador SW1
Control tipo P
NOTA: En los controles
Coaxitron, SW1 no se usa.
Coloque todos los
conmutadores en posición
de desactivación. Para
controles tipo D, consulte
la Tabla C.
Tabela B.
Configurações de Chave
para SW1
Controle tipo P
NOTA: Para controles
Coaxitron, SW1 não é
usada; configure todas as
chaves para OFF
(desligado). Para
sistemas de controle tipo
D, consulte a tabela C.
Tabelle A.
Schaltereinstellungen für
SW3
Baud-Raten-
Auswahlschalter
Tableau A.
Configuration du
commutateur SW3
Commutateur de sélection
de la vitesse de transfert
Tabella A.
Impostazioni
dell’interruttore per SW3
Interruttore di selezione
della velocità di
trasmissione
Tabelle B.
Schaltereinstellungen für
SW1
Steuerung Typ P
HINWEIS: Für
Steuerungen des Typs
Coaxitron controls wird
SW1 nicht verwendet;
stellen Sie alle Schalter
auf OFF. Zu den
Steuerungssystemen Typ
D siehe Tabelle C.
Tableau B.
Configuration du
commutateur SW1
Protocole de contrôle P
REMARQUE: Pour le
protocole de contrôle
Coaxitron, SW1 n’est pas
utilisé; mettre tous les
commutateurs sur OFF.
Pour les systèmes avec
protocole de contrôle D,
reportez-vous au tableau C.
Tabella B.
Impostazioni
dell’interruttore SW1
Controllo tipo P
NOTA: Per i controlli
Coaxitron non viene usato
l’interruttore SW1;
impostare tutti gli
interruttori su OFF. Per i
sistemi di controllo tipo D,
consultare la Tabella C.
SPECTRA
SWITCH SETTING
ADDRESS
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
1
OFF
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
OFF
4
ON
ON
OFF
OFF
OFF
5
OFF
OFF
ON
OFF
OFF
6
ON
OFF
ON
OFF
OFF
7
OFF
ON
ON
OFF
OFF
8
ON
ON
ON
OFF
OFF
9
OFF
OFF
OFF
ON
OFF
10
ON
OFF
OFF
ON
OFF
11
OFF
ON
OFF
ON
OFF
12
ON
ON
OFF
ON
OFF
13
OFF
OFF
ON
ON
OFF
14
ON
OFF
ON
ON
OFF
15
OFF
ON
ON
ON
OFF
16
ON
ON
ON
ON
OFF
SPECTRA
SWITCH SETTING
ADDRESS
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
17
OFF
OFF
OFF
OFF
ON
18
ON
OFF
OFF
OFF
ON
19
OFF
ON
OFF
OFF
ON
20
ON
ON
OFF
OFF
ON
21
OFF
OFF
ON
OFF
ON
22
ON
OFF
ON
OFF
ON
23
OFF
ON
ON
OFF
ON
24
ON
ON
ON
OFF
ON
25
OFF
OFF
OFF
ON
ON
26
ON
OFF
OFF
ON
ON
27
OFF
ON
OFF
ON
ON
28
ON
ON
OFF
ON
ON
29
OFF
OFF
ON
ON
ON
30
ON
OFF
ON
ON
ON
31
OFF
ON
ON
ON
ON
32
ON
ON
ON
ON
ON
Special Systems
Switch Number
1
2
3
4
5
6
7
8
AD-32 Preset System
On
CM9502 Setting
On
P Protocol Baud Rate
Switch Number
1
2
3
4
5
6
7
8
2400 Baud
Off
Off
Off
4800 Baud
On
Off
Off
9600 Baud
Off
On
Off