Xantech BXAUDIO4X4 User Manual

Page of 36
Model BXAUDIO4X4 
 
Page: 17 
© 2005 Xantech Corporation 
 
Primary Keypad 
Secondary Keypad 
Application 
Secondary 
Keypad 
Zone 
Termination 
Sensor 
Enable 
Secondary 
Keypad 
Zone 
Termination 
Sensor 
Enable 
One keypad in Zone with IR 
Sensor enabled 
OFF ON
ON 
 
Two Keypads in Zone with IR 
Sensors enabled 
OFF OFF
ON 
ON
ON
ON 
One Keypad and one separate 
IR Receiver in Zone 
OFF ON
 
OFF 
 
 
 
Two Keypads and two separate 
IR Receivers in Zone (Sub-
Zone) 
OFF OFF
OFF  ON
ON
OFF
Table 1 – LC4KP Keypad Jumper Configurations 
Multiple Keypad Connections 
1.  For a second keypad in the same zone, terminate the CAT5 cable in the same way as shown in Figure 10.
2.  Connect the CAT5 coming from the BXAUDIO4X4 Controller to the “CONTROLLER” jack on the Primary 
Keypad. Plug a CAT5 cable into the “EXPANSION” jack on the Primary Keypad and connect it to the 
“CONTROLLER” jack on the Secondary Keypad. Set the jumpers according to the above Table 1. 
 
3.   When adding an IR receiver in the zone, set the jumpers according to the above table and connect the 
cables as shown in Figure 10.