Motorola symbol ms120xfzy User Manual

Page of 24
8
Symbol MiniScan Family of Scanners
Triggering Options
Level Trigger
The laser is enabled and decode processing begins when 
the trigger line is activated. Decode processing continues 
until a good decode occurs, the trigger is released, or the 
Laser-On time expires. The laser is disabled once decode 
processing is complete. The next decode attempt does 
not occur until the trigger line is released and then 
reactivated.
Level
Pulse Trigger
The laser is enabled and decode processing begins when 
the trigger line is activated. The laser remains on and 
decode processing continues regardless of the trigger line 
until a good decode occurs, or until the Laser-On time 
expires. The laser is disabled once decode processing is 
complete. The next decode attempt does not occur until 
the trigger line is released and then reactivated.
Pulse