Crestron clw-dim1 dims1 slvd1 User Manual

Page of 12
 
CLW-DIM1, DIMS1, & SLVD1(W/A/B) 
Appendix: Wiring Diagrams 
Following are wiring diagrams for circuits that may be found when installing a dimmer: 
Stand-Alone Installations 
Figure 1: Wiring a CLW-DIM(S)1  
 
•  Since a -DIMS1 is installed without a slave, the blue lead of the -DIMS1 must be capped. 
If a neutral is not present in the wallbox, the wiring shown in the following diagram can be used. 
Figure 2: Alternative Wiring of -DIM1 and -DIMS1 Where Neutral is Not Present (Load-Fed Switch Loop) 
 
In the above configuration: 
•  The white wire from the -DIMS1 to the load is coded HOT. 
•  Since a -DIMS1 is installed without a slave, the blue lead of the -DIMS1 must be capped. 
•  The minimum load requirement is 100W.  
•  Bulb noise may be present even when the load is off. 
•  Circuits with small magnetic low-voltage loads may not work. 
8  
  Stand Alone Wall Box Dimmer:  CLW-DIM1, DIMS1, & SLVD 
Installation Guide – DOC. 6250A