Fuser replacement
The fuser is located inside the printer just behind the four 
image drum units.
   
Switch off the printer and allow the fuser to cool for about 
10 minutes before opening the cover.
1.
Press the cover release and open the printer’s top cover fully.
   
cover open button_F5_23.jpg
 
2.
Identify the fuser handle (1) on the top of the fuser unit.
WARNING!
If the printer has recently been powered on, some fuser 
components will be very hot. Handle the fuser with 
extreme care, holding it only by its handle, which will 
only be mildly warm to the touch. A warning label clearly 
indicates the area. If in doubt, switch the printer off and 
wait at least 10 minutes for the fuser to cool before 
opening the printer cover.