Linear AE-100 User Manual

Page of 36
20
PPN 64
64#TIME#
TIME = TIME UNTIL AUTO-DISCONNECT
(010-180 SECONDS)
MAXIMUM VISITOR TALK TIME
FACTORY SETTING: 60 SECONDS
PPN 63
63#TONE#
TONE = 0 FOR ACCESS RELAY TONE OFF
TONE = 1 FOR ACCESS RELAY TONE ON
SPEAKER TONE ON ACCESS RELAY ACTIVATION
FACTORY SETTING: RELAY TONE ON
PPN 77
77#CONTROL#
CONTROL = 0 TO DISABLE RESIDENT CONTROL
CONTROL = 1 TO ENABLE RESIDENT CONTROL
RESIDENT CONTROL OF ACCESS RELAY
FACTORY SETTING: RESIDENT CONTROL ENABLED
PPN 95
95#CALL-BACK#
CALL-BACK = 0 TO DISABLE RESIDENT CALL-BACK
CALL-BACK = 1 TO ENABLE RESIDENT CALL-BACK
RESIDENT CALL-BACK
FACTORY SETTING: RESIDENT CALL-BACK DISABLED
STANDARD PROGRAMMING METHOD
System Options (Continued)
Speaker Tone on Access Relay Activation
The factory setting will cause the speaker to sound a tone for two seconds 
when the access relay is activated. Alternately, the tone can be turned 
off.
1. Press     
2.  Select the option for access relay activation tone:
Enter 0 to turn OFF the access relay activation tone.
• 
Enter 1 to turn ON the access relay activation tone.
• 
3. Press 
Maximum Visitor Talk Time
Visitors will converse with residents over the telephone until the resident 
grants or denies access. If the resident responds to the visitor’s request 
by pressing their telephone key, the system will hang up and release 
the telephone line. If for some reason the resident does not press 
the telephone key or does not hang up, the system will automatically 
disconnect the visitor after 60 seconds.
At ten and fi ve seconds before the disconnect, a tone will sound on the 
telephone to remind the resident of the pending disconnect. The resident 
can extend the talk time by pressing the # key on their telephone. The 
disconnect time can be adjusted from 10-180 seconds.
1. Press
 
 
 
 
2.  Enter the disconnect time in seconds (010-180):
3. Press
 
Resident Control of Access Relay
The factory setting allows the resident to activate the access relay by 
pressing the 9 key on their telephone when a call from the AE-100 is 
received. This feature can be disabled. Disabling this feature will only 
allow access by using resident Entry Codes and Stand-alone Entry 
Codes at the unit’s keypad.
1. Press     
2.  Select the option for resident access relay control:
Enter 0 to turn OFF resident access relay control.
• 
Enter 1 to turn ON resident access relay control.
• 
3. Press 
Resident Call-back
The resident call-back feature allows the AE-100 to answer the telephone 
and switch to speakerphone mode if the telephone call is within 
60 seconds of the last use of the AE-100. This feature gives residents the 
capability to call a visitor back in case of a recently missed call.
This feature can only be used in single unit installations.
The factory setting disables the resident call-back feature. Alternately, 
this feature can be enabled.
  NOTE: The Automatic Telephone Answer feature (PPN #61) must also be 
enabled for the resident call-back feature to function.
1. Press     
2.  Select the option for resident call-back:
Enter 0 to turn OFF the resident call-back feature.
• 
Enter 1 to turn ON the resident call-back feature.
• 
3. Press