Intermatic 158ml12897 User Manual

Page of 2
Use chart at right to 
determine the mini-
mum gauge cable to 
be used, depending 
on the wattage of 
the power pack. Us-
ing larger cable will 
increase light output. 
For Malibu cable, contact your supplier. WARNING—RISK OF FIRE: 
Do not use cable smaller than listed in the table.
Malibu cable is prepared, ready to con-
nect to the power pack. If using other 
cable, split one end of cable for about 
3”, being careful when splitting NOT to 
expose the copper wire. Then strip 5/8” 
of insulation from the end. Also, refer to 
strip length guide on the power pack.
5/8“
3”
5/8“
3”
Lay power pack on a flat, stable surface and insert 
the stripped end of one wire under terminal clamp-
ing plate A. Then tighten the screw. Repeat this 
procedure for clamping plate B. Do not exceed the 
wattage rating of the power pack. NOTE: The C 
terminal is only used to connect an optional photo 
control. WARNING—RISK OF FIRE: Make sure there is no wire 
insulation under the clamping plate, and firmly tighten the terminal 
screws.
Terminal Blocks
A B C
Terminal Blocks
A B C
Route the low-voltage cable to fixtures. If there is extra cable, coil it 
after last fixture or cut it off and discard. If you are using cable that 
came with power pack and fixtures, leave about 12” of cable after 
the last fixture. Be sure to leave at least 10 wire feet between the 
power pack and first fixture. Do not yet hide or bury cable. WARN-
ING—RISK OF FIRE: Do not coil cable around power pack.
Locate the manual ON/OFF switch on power pack and move it to 
the ON position.
1
  Select Cable 
3
  Prepare Cable 
4
  Connect Cable to Power Pack 
Mount power pack vertically outdoors 
only. WARNING—RISK OF FIRE OR 
ELECTRICAL SHOCK: Make sure Power 
Pack is at least 1 foot above ground 
and at least 10 feet from pool or spa. 
Plug into GFCI outdoor electrical outlet 
protected by a weatherproof cover (not 
supplied–Malibu recommends genuine 
Intermatic weatherproof covers). Make 
sure outlet is working.
12”
GFCI
12”
GFCI
7
  Turn Power Pack ON
6
  Run Cable 
Attach fixtures to cable using cable connectors as 
shown. Place one connector on each side of cable, 
then press together to lock. Prongs will pierce cable 
to make contact, and fixture should light up.
8
  Attach Fixtures to Cable 
Set ON and OFF times by setting tripper locations:
Insert a red ON tripper (A) at the time you want 
the lights to turn on.
Insert a black OFF tripper (B) at the time you 
want the lights to turn off.
Use a second set of red and black trippers if you 
want another ON/OFF cycle.
a.
b.
c.
A
B
A
B
9
  Set Timer ON / OFF Times 
Set time of day on the timer as follows:
Make sure the Power Pack is plugged in and 
turned ON.
Turn the dial to the present time of day as 
shown by the arrow (C).
Turn the dial one or more complete revolutions, 
then return to the present time of day.
The lights will now turn ON and OFF at the times you have set.
You can manually operate the lights by turning the Manual ON/OFF 
Switch (D).
a.
b.
c.
C
D
C
D
10
  Set Time of Day
Once all fixtures are in place and you are satisfied with their loca-
tions, cable may be protected by covering or burying up to 3” deep. 
Remember, if you are using cable that came with the power pack 
and fixtures, leave about 12” of cable after the last fixture and lay 
excess cable between fixtures. WARNING—RISK OF FIRE: Do not 
coil excess cable except after the last fixture.
11
  Protect or Hide Cable 
Power Pack Wattage
Minimum Gauge Cable
217-300
12
157-216
14-12
121-156
16-14-12
0-120
18-16-14-12
ML200RT Model / Modelo / Modèle 
POWER PACK / TRANSFORMADOR / BLOC D’ALIMENTATION
Lay the fixtures out where you want to locate them. The first 
fixture should be at least 10 wire feet from the power pack. Mount 
them permanently if you wish. WARNING—RISK OF ELECTRICAL 
SHOCK: Do not place a fixture within 10 feet of a pool or spa.
2
  Place Fixtures 
Mount power pack vertically at least one foot above ground. Do not lay 
on the ground.
Plug power pack directly into an outdoor GFCI outlet with a weather-
proof cover marked “wet location.” Do not use extension cords.
Mount power pack at least 10 feet from pool or spa.
When connecting wire at terminals, do not allow insulation to get under 
the clamping plate, and firmly tighten the terminal screws.
Do not use cable smaller than listed in the table below.
Do not coil extra cable around the power pack. Either cut off extra 
cable and discard, or leave at the end away from the power pack.
Do not repair or tamper with cord or plug.
Do not submerge power pack.
Do not connect two or more power packs in parallel.
Do not use with a dimmer.
If house circuit breaker trips when power pack is turned on, unplug 
power pack from AC outlet, correct fault, restore power, then reset 
circuit breaker.
Power pack and fixtures must be installed in compliance with national 
and all local electrical codes and ordinances.
If necessary to splice cable, carefully follow instructions that came 
with the connector you have purchased.
WARNING: Risk of Fire or Electrical Shock
Make sure power pack is plugged in. Is outlet working?
Turn timer manual switch to “ON” or rotate dial so “ON” tripper passes 
time line indicator.
Is lamp burned out? Use another lamp to test.
NOTE: This lighting system is designed to last many years under normal 
conditions. However, lamps eventually burn out and operating with one 
lamp out can shorten the life of the others. Conditions beyond control 
(high input voltage, poor voltage regulation, etc.,) will also affect lamp 
life. IT IS IMPORTANT TO REPLACE BURNED OUT LAMPS PROMPTLY.
 Suggestions to Solve Problems Quickly 
5
  Mount Power Pack 
VEUILLEZ LIRE LES DIRECTIVES 
AVANT D’UTILISER CE PRODUIT.
READ INSTRUCTIONS BEFORE 
USING THIS PRODUCT.
LEA LAS INSTRUCCIONES ANTES 
DE USAR ESTE PRODUCTO.
El cable de Malibu está preparado, listo 
para conectarlo al transformador. De lo 
contrario, si usa otro cable, separe un 
extremo del cable aproximadamente 3 
pulgadas (7,6 cm), tenga cuidado cuando 
lo separe de NO exponer el hilo de co-
bre. Después, retire 5/8 pulgadas (16 mm) del aislante del extremo. 
Consulte la guía de longitud de desforre del transformador.
16 mm
7.6 cm
16 mm
7.6 cm
3
  Preparación del cable 
Instale el transformador en una superficie plana y 
estable e inserte el extremo sin material aislante 
debajo de la placa de fijación del terminal A. Lu-
ego, apriete el tornillo. Repita este procedimiento 
para ajustar la placa de fijación B. No exceda la 
capacidad nominal de vatiaje del transformador. 
NOTA: El terminal C se usa sólo para conectar un control fotoeléc-
trico opcional. ADVERTENCIA—RIESGO DE INCENDIO: Asegúrese 
que el aislante no se encuentre debajo de la placa de fijación y los 
tornillos de la terminal estén firmemente ajustados.
Bloques de Terminales
Bloques de Terminales
4
  Conexión del cable al transformador 
Use la tabla que 
aparece a la derecha 
para determinar el 
calibre mínimo del 
cable que se va a 
usar, dependiendo 
del vatiaje del trans-
formador. Al usar un 
cable más grande 
aumentará la emisión luminosa. Para conseguir un cable de Malibu, 
comuníquese con su proveedor. ADVERTENCIA—PELIGRO DE 
INCENDIO: No use cables más pequeños de los que se mencionan 
en la tabla.
1
  Selección de un cable
Vatiaje del  
transformador
Calibre mínimo  
del cable
217-300
12
157-216
14-12
121-156
16-14-12
0-120
18-16-14-12
Instale las lámparas en el lugar deseado. La primera lámpara se 
debe instalar a una distancia mínima de 10 pies (3 m) del transfor-
mador. Si lo desea instálelas en forma permanente. ADVERTEN-
CIA—PELIGRO DE DESCARGA ELÉCTRICA: No instale una lámpara 
a menos de 10 pies (3 m) de una piscina o spa.
2
  Instalación de las lámparas 
Instale el transformador en forma vertical al menos un pie (30 cm) sobre 
el suelo. No lo instale en el suelo.
Conecte el transformador directamente a un tomacorriente GFCI exte-
rior protegido por una cubierta protectora contra la intemperie marcada 
como apta para “lugares humedos”. No use cables de extensión.
Instale el transformador al menos a 10 pies (3 m) de la piscina o spa.
Al conectar el cable a las terminales asegúrese que el aislante no se 
encuentre debajo de la placa de fijación y los tornillos de la terminal 
estén firmemente ajustados.
No use cables más pequeños de los que se mencionan en la tabla que 
aparece a continuación.
No enrolle el cable sobrante alrededor del transformador. Puede cortar 
el cable sobrante y desecharlo o bien, dejarlo hasta el extremo lejos 
del transformador.
No repare ni modifique de ninguna manera el cable o enchufe.
No sumerja el transformador.
No conecte dos o más transformadores en paralelo.
No lo utilice con un atenuador de luz.
Si el cortacircuito salta cuando se enciende el transformador, des-
enchúfelo del tomacorriente de CA, corrija la falla, vuelva a restablecer 
la red eléctrica y active nuevamente el cortacircuito.
El transformador y las lámparas se deben instalar de acuerdo con todos 
los códigos y normas nacionales y locales.
Si es necesario empalmar cables, siga atentamente las instrucciones 
que se incluyen con el conector que adquirió.
ADVERTENCIA: Peligro de incendio o descarga eléctrica
Instale el transformador en forma verti-
cal en exteriores solamente. ADVER-
TENCIA—PELIGRO DE INCENDIO O 
DESCARGA ELÉCTRICA: Asegúrese de 
instalar el transformador al menos 1 pie 
(30 cm) sobre el suelo y por lo menos a 10 
pies (3 m) de una piscina o spa. Conéctelo 
a un tomacorriente eléctrico GFCI exte-
rior protegido por una cubierta protec-
tora contra la intemperie (no se incluye, 
Malibu recomienda cubiertas protectoras 
contra la intemperie originales de Intermatic). Asegúrese de que el 
tomacorriente esté en buen estado.
30 cm
GFCI
30 cm
GFCI
5
  Instalación del transformador 
Extienda el cable de bajo voltaje hasta las lámparas. Si sobra cable, 
enrolle el cable sobrante después de la última lámpara o córtelo y 
deséchelo. Si está usando el cable que viene con el transformador y 
las lámparas, deje aproximadamente 12 pulgadas (30 cm) de cable 
después de la última lámpara. Asegúrese de dejar al menos 10 pies 
de cable entre el transformador y la primera lámpara. No oculte ni 
entierre el cable todavía.  
ADVERTENCIA—PELIGRO DE INCENDIO: No enrolle el cable so-
brante alrededor del transformador.
6
  Cable tendido 
For Missing / Damaged Parts from Newly Purchased Products:
Si el producto que acaba de adquirir está incompleto o tiene piezas dañadas, noti-
fique el problema a través de:  
En cas de pièces manquantes / endommagées dans des produits tout neufs: 
www.intermatic.com/warranty  
or/o/ou  1-800-492-2289
For Customer Service or To Purchase Replacement Parts, call:
1-815-675-7000
158ML12897