Problem Solving
Troubleshooting
The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
assistance is required, please contact a Crestron customer service representative.
C2ENET-1/-2 Troubleshooting
Trouble
Probable Cause(s)
Corrective Action
C2ENET-1/-2 improperly
installed.
installed.
Follow installation procedures in this
guide.
guide.
Improper Ethernet
connection.
connection.
Verify proper connection at Ethernet
port.
port.
Damaged connector
pins.
pins.
Follow installation procedures in this
guide and inspect connector pins.
guide and inspect connector pins.
Incorrect
firmware/software.
firmware/software.
Update firmware/software versions per
the specifications in this guide.
the specifications in this guide.
Communications via
the LAN port is not
functioning.
the LAN port is not
functioning.
Another device on the
LAN has the
same/conflicting IP
address.
LAN has the
same/conflicting IP
address.
Disconnect NET/IP cable from the
control system. Ping the IP address of
the control system. If a reply occurs,
obtain a new static IP address for the
control system.
control system. Ping the IP address of
the control system. If a reply occurs,
obtain a new static IP address for the
control system.
Conflicting IP address
window opens after
entering IP addresses
in new IP address
fields.
window opens after
entering IP addresses
in new IP address
fields.
IP Subnet for LAN A and
LAN B match (C2ENET-
2 only).
LAN B match (C2ENET-
2 only).
Change LAN B IP address so that WAN
and LAN no longer conflict.
and LAN no longer conflict.
Objects on Web page
do not draw correctly.
do not draw correctly.
File transfer error.
Reload Web page project.
Cannot communicate
with control system
through router.
with control system
through router.
Appropriate port not
open through router.
open through router.
Verify port 80 is open for Web hosting.
Verify port 41795 is open for Crestron
diagnostics. Verify port 41794 is open
for CIP.
Verify port 41795 is open for Crestron
diagnostics. Verify port 41794 is open
for CIP.
Control system runs
slow or crashes on
LAN.
slow or crashes on
LAN.
Potential virus on Web
port 80.
port 80.
Change Web port via Viewport using
console commands, or click the
Advanced button in the Ethernet
Configuration window. (Refer to
“Advanced Settings (optional): on
page 9 of this guide.
console commands, or click the
Advanced button in the Ethernet
Configuration window. (Refer to
“Advanced Settings (optional): on
page 9 of this guide.
Operations & Installation Guide – DOC. 5962B
2-Series Ethernet Interface Expansion Cards: C2ENET-1 & C2ENET-2
• 19