Garmin da42-l360 User Manual

Page of 102
Garmin G1000 Cockpit Reference Guide for the DA42-L360
190-01062-01  Rev. A 
56
Annunciations & Alerts
Flight
Instruments
EIS
Nav/Com/
XPDR/Audio
AFCS
GPS Nav
Flight
Planning
Pr
ocedur
es
Hazar
d
Avoidance
Additional
Featur
es
Abnormal
Oper
ation
Annun/
Alerts
Appendix
Index
Annunciation 
Window text
Alerts Window message
Audio 
Alert
STAL HT OFF
Stall warning heat is off.
Single 
Aural Tone
STICK LIMIT
Stick limiting system has failed.
L VOLTS LOW
R VOLTS LOW
Left bus voltage is less than 25 volts.
Right bus voltage is less than 25 volts.
AnnunCiAtiOn ADvisOrY Alerts
Annunciation 
Window text
Alerts Window message
Audio 
Alert
L FUEL XFER
R FUEL XFER
Left fuel transfer from aux to main in progress.
Right fuel transfer from aux to main in progress.
No Tone
Alert messAge
Alerts Window message
Audio 
Alert
PFD FAN FAIL
 – The cooling fan for the PFD is inoperative.
None
MFD FAN FAIL
 – The cooling fan for the MFD is inoperative.
GIA FAN FAIL
 – The cooling fan for the GIAs is inoperative.
AFCs Alerts
Condition
Annunciation  Description
Pitch Failure
Pitch axis control failure.  AP is inoperative.
Roll Failure
Roll axis control failure.  AP is inoperative.
MET Switch Stuck, or 
Pitch Trim Axis Control 
Failure
If annunciated when AP is engaged, take control 
of the aircraft and disengage the autopilot.  If 
annunciated when AP is not engaged, move each 
half of the MET switch separately to check if a 
stuck switch is causing the annunciation.
System Failure
AP and MET are unavailable.  FD may still be 
available.
Yaw Damper Failure
Yaw Damper control failure.